User login

Maintenance for DRP-10

Date: 
Monday, July 29, 2019
Synopsis: 
Contoller box exchanged.
Equipment/Beam Line: 
Description: 

9790 hrs I noticed that when the pump has been running for a while and is stopped till the fan stops turning then the pump doesn't go back on by the on switch.  The fan labours and doesn't turn fast enough to trigger the pump to start.  I used the controller box from DRP 17 which was at 7007 hours before it died.  The controller box fixed the issue. 

Author: 
Deepak Vyas